Aug 11 2017

Intelligent water meter/IC card water meter Battery

IC Card Water meter/intelligent water meter is an intelligent water meter products, at this stage has begun to promote the application of many pilots, because it is necessary to install the battery, to work, display data, so some users have produced such questions: if the IC card water meter/intelligent water meters is power off, will the water supply be cut off?

Multi Jet Water Meter     Prepaid water meter  

intelligent water meters need to recharge to buy a drink to use, after buying water on the meter inserted IC card, to water. However, in the use of the process, because of forgetting to replace the battery, many users found that the insertion of IC card, LCD screen has not shown the number, at this time will occur two kinds of possible problems, one is inserted card, water meter does not show the number, but the supply of normal tap. There will also be a situation, that is, immediately water. What are the reasons for these two different situations? This is because the IC card water meter/intelligent water meter motherboard battery and panel battery is different, if the LCD is not displayed, and will not affect the user normal water, at this time the user should replace the battery as soon as possible. And if the real water supply in the home, then there is almost only one reason, that is, intelligent meter monitoring to run out, automatic to the brake plate issued a signal.

 AWWA Standard Water MeterRemote Reading Water Meter

If the home is out of water, and the water meter screen after the card does not show, there may be battery exhausted, can not work, you can replace the same type of battery. The following is a description of the replacement battery steps:
1, cut the battery compartment seal, remove the fixed cover of the screw, remove the battery. The battery compartment is on the bottom of the meter.

Woltman Type Water Meter

Single Jet Dry Dial Brass AMR Remote Reading Water Meter

Single Jet Dry Dial Brass AMR Remote Reading Water Meter

2, press the buckle, unplug the connector, disconnect the battery snap connection. Water meter used for two 3V lithium battery, model CR14505E two series, the battery and the water meter by the buckle connection.
3, the new battery to buy, pay attention to whether the positive and negative batteries with the original battery, mainly to see the connection line. If correct, plug the buckle with the water meter can be inserted.
5, at this time without worry on the battery cover cover, first with their own water card into the water meter, insert the water meter after the solenoid valve action, the screen shows the relevant figures, that the battery work properly, the water meter can work. Note: There may be a small amount of water in the water meter.

Ultrasonic Water Meter
6, cover the battery cover, screw on the screw, if the water meter has been replaced, call the property staff to change the water meter on it

 

Dry Type Drinking Cold Water Meter

Dry Type Drinking Cold Water Meter

Apr 21 2015

Agricultural irrigation use IC card water meter

Peking Gazette net news (reporter Liu Feifei’s Yu Tie) early on August 9, the reporters came to Daxing town, Nan Li Qu village farmers xiāo shàn jūn vegetable greenhouses, old Shaw opened the faucet, thin water outlet from the micro-spray system evenly poured in on the lettuce. Xiāo shàn jūn said happily: “now how much water a computer calculated, scientific and water. “Today, in this village 60 greenhouse greenhouse, 696, all computerized calculation, IC card control of water consumption water irrigation, water cooler 50%.

Xiaodong of the village water users Association staff told reporters that the farmer water users Association has developed a manual for the operation and management of the regulations, the system employs 4 pipe water to water to implement patch management. They installed water meters in each greenhouse, greenhouses, filters and other equipment, implements water-by-Studio measurement. User 3 days before the start of the growing season each shed, fill in the registration form for crop cultivation, according to different crops irrigation, by computing each greenhouse’s annual water quota and each plans to shed water, determine the yearly water consumption of each eye tube wells, and entered into a computer. System not only can be used to query greenhouses, farmers and the motor-pumped well water, water use in each shed can also be released to the public, and accept supervision by the masses.

“Look at this POS machine, now peasants from which all water used for irrigation per year IC card data input, then through IC card control each motor-pumped well water, scientific irrigation. “Staff of the Association said, agricultural water quota management system, completely change the phenomena of extensive irrigation, metering and billing are not allowed, improved irrigation management level.
Source:http://www.asmeter.com/

Apr 17 2015

Analysis of smart IC card water meter specifications

Smart IC card water meter is placed in indoor use, so their use of environmental requirements is not high. Only the meter is usually placed in locations near the kitchen, so there is a problem to prevent water erosion and soot pollution. Those problems are not difficult to solve. Prevent water sealing technology for as long as is reasonable, generally meet the requirements. But preventing smoke pollution, just do something on the IC card technology such as dust cover, and it can be resolved. Following an analysis of several important specifications.
1, the battery life indicator. This is an important indicator. Gas meter in this area to address the bad. Some gas meter requires the user to change the battery a few months, it’s not science. Now low-power design can make a smart IC card water meter do not change battery life up to 8 or even 10 years. If you reach such a level, and water sectors will be very convenient to the user. Of course, meter mechanical metrology, and life of the electrical control should be higher, after replacing the battery, should continue to be used over a long period of time.

2 the entire table service life. Service life of the entire table is a question worth exploring. Because the whole life of the table in theory, is decided by the shortest life expectancy of the device. Then, use the shortest life expectancy of the device is that? According to the national standards, this device is a meter, but in fact, the meter uses the term far exceeded national standards for years, we can see that this criterion was unreasonable. From its current manufacturing situation, manufacturers committed to life expectancy index 6 years is reasonable. In practice, however, the life of more than 10 Smart IC card water meter is entirely possible.
3, damp-proof and sealing performance. Sealing problem has already been mentioned above. As long as the electrical part of a sealed deal, coupled with some anti-wet treatment means, above 85% specification should be no problem. Vibration-proof performance. Water meter in the transportation and installation of vibration problems will arise. To be considered for this indicator. Generally speaking reached 1g levels are sufficient.

4, physical damage indicators. Generally speaking, as long as the use of good overall shell of protection measures, is generally able to meet conservation requirements. Of course, the use of IC card water meter, its decks are vulnerable parts, this is a problem that cannot be solved. Software protection so it is considered processing, making attacks on the deck is not very helpful, even if the card holder is broken, does not affect the other parts of IC card water meter working properly. But from a practical point of view, this is not a serious problem. IC card water meter is installed on the user’s home, using targeted, and meter is the property of the user, without special reason, users and will not attack the dashboard. Cannot be considered unrestricted and strengthening the instrument of attack resistance of, but to deliberately imposed by the acts of sabotage can be identified and punished accordingly.
5, anti-electromagnetic interference indicators. Electromagnetic interference is not a significant indicator. Home environments above 2000 volts static electric field such conditions rarely. Normal use of electromagnetic intensity could not reach the intensity can damage people and other electronic products, so the targets set at 2000 volts is enough.
6, freeze-proof specifications. Anti freeze problem is primarily a method of storage and use, for example, in freezing temperatures, to do the drainage to prevent ice rise, this is obviously a question of management. Temperatures below freezing do not have to consider the use of meter, because the water had frozen, beyond measure. But in the course of transportation and storage, may experience far below freezing temperatures, it will need to consider. The reasonable index values should be within the range of-25 to +50, in this range, the meter should not be damaged when the temperature returns to normal temperature, water meters should be able to work properly.
Conclusion: with the development of science and technology, smart IC card water meter will be constantly developed and perfected. For example, now this old water meters on collecting the signal pattern will be replaced by advanced water flow signal extraction device, mechanical measurement display and mechanical parts will be eliminated, and will focus on one of the tables and valve and so on. In General, smart IC card water meter is an advanced measuring instruments, the large-scale promotion of the use of such advanced instrumentation for water management will contribute to China’s modernization process.
Source:http://www.asmeter.com/

Jul 30 2014

The characteristics of prepayment water meter, installation notes, classification, use and disposal of common problems

The traditional “water first, pay after” into “first payment, after the water”, to effectively solve the charge problem. The detailed design process uses the EM78 series single-chip design of specific hardware circuit diagram and software is given..

prepayment water meter

(1) does not need manual meter reading, and is conducive to modern management. With the “one table” one household, the meter number of power supply enterprise management has increased dramatically, the installation of prepayment electric energy meter is used for

Strengthen the modernized management of electric enterprises, improve the service level of a best choice. The use of prepayment electric energy meter also avoid manual meter reading to the inconvenience charges to bring customers, and historical data can prepayment water meter, easy for customers to query.

(2) fully reflects the commodity attribute of water. Prepaid water meter according to the principle of commodity exchange, the first water after the water, completely changed the traditional water charging mode, fully embodies the commodity property of hydraulic. Customers can according to their actual needs to plan to buy water, water, no late fees and because of arrears, adding unnecessary expenses.

(3) to solve the problem of fees. 1, the use of radio frequency card, without any exposed electrode, moisture-proof performance, easy to use.

2, through the double key encryption card, a card a secret.

3, with a card table, or a card table function.

4, with the remaining water is insufficient, prompting the user to buy water.

5, with the battery voltage is too low, to prompt the user to replace the battery.

5, with the battery voltage is too low, to prompt the user to replace the battery.

6, has the data read back, when the user card to the management center for water, can use the card corresponds to the cumulative water consumption in the water meter, battery status, interference frequency read back to the management center.

7, small starting flow, high precision.

8, display function: surplus for the purchase of water, water, with a total content and other parameters can be effectively displayed on the LCD screen, the user can through the user card check table in the surplus water and total water use information.

Installation:

Installation:

1, choose water should be used according to the pipeline flow less than or close to common flow meter is appropriate, not only to determine the water pipe diameter.

2, the installation location to avoid light pollution, drying, freezing, the frozen period, in addition to water pipes wrapped insulation, when not in use the water inlet end of the valve is closed, the outlet valve and open the water tap, can prevent water frost damage.

The meter must be installed level, so that the literal upward.

Installation of piping must be inside the tube gravel, silt, hemp and other debris washed clean after the installation of water meters, so as to avoid the water meter malfunction.

Installation of piping must be inside the tube gravel, silt, hemp and other debris washed clean after the installation of water meters, so as to avoid the water meter malfunction.

In order to measure accurately, the tap should be higher than the water.

The water meter installed on the boiler into such as pipes, should be installed check valve, prevent the return of hot water scalding water.

The water should not be directly connected with the pipeline, water meter and the pipeline should active interfaces (such as pipe joints, connecting screws, over the sealing gasket etc.). The installation of brass body IC card water meter, should not be excessive force caused by pipe and pipe fitting, so as not to damage the water meter.

The meter must be installed in the floor drain and smooth drainage.

The meter must be installed in the floor drain and smooth drainage.

Seven, transportation and storage

1, the water transportation should not be subject to severe shock. Save water meter should be in the original packaging, preservation of the local environmental temperature 0 ℃ -60 ℃, relative humidity below 95%, non corrosive gas in the air.

The water in the warehouse storage, stacking height of not more than 10 box, water meter stack single package put height of not more than 10, not only the water meter packaging open storage.

http://www.asmeter.com